Refer to the user manuals and documentation for C.CURE® 9000 and Milestone XProtect® Corporate for a comprehensive description of the installation, configuration and features of the respective systems. 7.1.1 Licenses. Obtain integration license from Software House and apply license using the C.CURE® licensing tool.

Page 2: R8 output module, Optional metal enclosures with tamper switch, Model numbers, Wiring summary, Wiring configuration diagram

Advertising

s p e c I F I c A T I O n s

Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies
by region; contact your sales representative. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.

© 2008 Tyco International Ltd. and its respective companies. All rights reserved. SH0146-DS-200810-R01-LT-EN

(*) For plenum or underground applications, use Belden 89182 for one pair 22 AWG, 100 ohm 12.95 pf/ft.

Note: Control, supervised, and unsupervised input cables must be shielded for FCC Class B operation.

General

Dimensions (H x W) . . . . .11.0 x 15.0 cm (4.3 x 5.9 in)

Environmental . . . . . . . . . . 0° to 50° C (32° to 122° F); 5 to 85% relative

humidity, non-condensing

Power Input Voltage . . . . .12 VDC +/- 10%

Tamper . . . . . . . . . . . . . . .Dedicated input for external tamper switch

Weight. . . . . . . . . . . . . . . .0.23 kg (8 oz)

Regulatory . . . . . . . . . . . . UL 294, UL 1076, FCC Part A

CE, EN 50133, ROHS

I8 Input Module

Power Requirements . . . .180 mA @ 12 VDC

Inputs . . . . . . . . . . . . . . . .Eight Class A supervised

LEDs per Input . . . . . . . . . Red (alarm), green (normal), and yellow

(supervision error)

I8-CSI Input Module

Power Requirements . . . .80 mA @ 12 VDC

Inputs . . . . . . . . . . . . . . . .Eight Class A supervised, configurable via DIP switch

LEDs per Input . . . . . . . . . Red (alarm), green (normal) and yellow

(supervision error)

Circuits Supported . . . . . . Single resistor: 1K, 5K, 10K

Double resistor: 1K, 5K, 10K,

1K/2K, 6.8K/18K, 200/10K

Unsupervised: NO, NC

R8 Output Module

Power Requirements . . . .45 mA @ 12 VDC plus 32 mA per active relay

Outputs. . . . . . . . . . . . . . .Eight Form C dry contact relays

LED per Output. . . . . . . . .Red (relay active)

Relay Contact Ratings . . . 30 VDC, 2.0 A resistive

30 VDC, 1.0 A inductive

125 VAC, 4.0 A

Optional Metal Enclosures with Tamper Switch

RM-DCM-CAN

Dimensions. . . . . . . . . . .356 x 305 x 89 mm (14 x 12 x 3.5 in)

Capacity . . . . . . . . . . . . .Up to four input or output modules

RM-CAN

Dimensions. . . . . . . . . . .210 x 184 x 83 mm (8.25 x 7.25 x 3.25 in)

Capacity . . . . . . . . . . . . .One input or output module

Model Numbers

AS0073-001 . . . . . . . . . . .I8 input module

AS0073-CSI . . . . . . . . . . .I8-CSI input module

AS0074-000 . . . . . . . . . . .R8 output module

RM-DCM-CAN . . . . . . . . .Large metal enclosure with tamper switch

RM-CAN . . . . . . . . . . . . . .Small metal enclosure with tamper switch

Wiring Summary

Signal

From

To

Belden #

Gauge

# of Pairs

Shielded

Maximum Length

Comm

(two-wire RS485)

apC/iSTAR

I8/R8

9841*

24

1

Yes

1,220 m

(4,000 ft)

Power

apC/iSTAR

I8/R8

9841*

24

1

No

Based on

voltage drop

Control Point

R8

Strike, Siren, etc.

8442/8461

18

1

No

Based on

voltage drop

Supervised Input

I8

REX or Door Contact

8442/8461

22/18

1

No

610 m (2,000 ft)

Wiring Configuration Diagram

I8

In

pu

t M

od

ule

C

on

fig

ur

at

ion

R8

O

ut

User Guide Software

pu

t M

od

ule

C

on

fig

ur

at

ion

0

1

2 3

F

E DCB A

4 5

6

7

8

9

1

SW1

4

SOFTWARE HOUSE

MADE IN USA

P9

P2

P3

P4

P8

Software for user manual writing

P7

P6

P5

W1

TAMPER

INPUT

P1

R8 OUTPUT MODULE

AS-0074-000 REV.A

NO

NO

NO

NO

NO

NO

NO

NO

NC

NC

NC

NC

NC

NC

NC

NC

C

C

C

C

C

C

C

C

NOTE: All mounting holes are 1/8' dia.

Max. component height 1/2'.

2 3

1

2
3

1

2
3

1

2
3

1

2
3

1

2

3

1

2

3

1

2

3

1

2

3

I8

-C

S

I I

np

ut

M

od

ule

C

on

fig

ur

at

ion

Pb

Pb-Free

P5

INE

1

P6

INF

1

P7

ING

1

P8

INH

1

P10

P9

GND

GND

TS

+D

-D

+12V

1

1

P4

IND

1

P3

INC

1

P2

INB

1

P1

INA

1

S1-1 ON = LED Power

S1-2 ON = Disable Tamper

S1-3 ON = Not Used

S1-4 ON = 485 Termination

DS4

DS25

DS3

DS2

DS27

Y1

DS26

DS1

DS24

DS23

DS22

S3

1

2

3

4

NO

DS21

DS20

DS7

DS6

DS5

DS10

DS9

DS8

DS13

DS12

DS11

S3

DS19

DS18

DS17

DS16

S2

1

2

3

4

ON

DS15

DS14

S2

S1

U3

FOR SWH STD 1K DUAL S2:3-4, S3:1-4 = OFF
SEE QUICKSTART DOC FOR OTHER SETTINGS
CYCLE POWER AFTER SETTING

1

2

3 4

ON

S1

SW1

1

TYCO

SOFTWARE HOUSE

Software For User Manual Writing

ASSEMBLED IN USA

C

COPYRIGHT 2007

'WARNING Damage may result from incorrectly

wiring power terminals, input and output lines, and

central-supervising station lines. Check all

connections before powering the unit.'

0312–5008–01 Rev.

18–CSI BOARD

®

Input Rating P9

12VDC 125mA

Refer to Quick Start Installation Guide,

P/N UM-218, Rev B0, July 2008